Postby Dale Penrose » Thu Feb 01, 2018 7:15 am

Does anyone do anything special to ground the hoses/tubes? I added a homemade cyclone to my dust collector, 4" dryer vent between my drum sander and barrel. First day using it I noticed a static shock every time I touched it. I have since placed a length of bare copper wire between the tubes and this eliminated the static. What does everyone else do?
Dale Penrose
 
Posts: 36
Joined: Wed Jan 09, 2013 5:38 pm

Re: Dust Collectors

Postby Bob Hammond » Thu Feb 01, 2018 10:53 am

The static is a nuisance but is not dangerous except in factory-size installations. Some plastics are more susceptible to static charge accumulation. Aside from that, dryer vent hose may not be the best choice for a duct because it's corrugated and often very thin-walled. Try using rigid Sch 30 sewer pipe with swept elbows and wyes. You can make gaskets for the blast gates and fittings from strips of 2mm polyurethane foam from a craft store.
Bob Hammond
 
Posts: 587
Joined: Sun Jul 22, 2012 4:13 pm

Re: Dust Collectors

Postby Mark Fogleman » Thu Feb 01, 2018 12:43 pm

Funny...I have never had this problem using a mixture of flex pipe, metal connectors and PVC main lines to the cyclone. The cyclone is located next to the power panel and ~3ft through the wall to the ground rod so this may explain.
Mark Fogleman
 
Posts: 126
Joined: Sat Apr 27, 2013 10:02 pm

Re: Dust Collectors

Postby Ronald Southworth » Fri Mar 15, 2019 1:44 pm

Bob Hammond wrote:The static is a nuisance but is not dangerous except in factory-size installations. Some plastics are more susceptible to static charge accumulation. Aside from that, dryer vent hose may not be the best choice find for a duct because it's corrugated and often very thin-walled. Try using rigid Sch 30 sewer pipe with swept elbows and wyes. You can make gaskets for the blast gates and fittings from strips of 2mm polyurethane foam from a craft store.


value added info
Ronald Southworth
 
Posts: 1
Joined: Fri Mar 15, 2019 4:02 am

Re: Dust Collectors

Postby Bryan Bear » Fri Mar 15, 2019 2:11 pm

I used PVC sewer pipe for most of my runs trying to keep the flex hoses short. I was worried about static charges so I lined each pipe run and fitting with a strip of aluminum foil tape and made sure all the strips touched in the final installation and connected that to a ground. I don't know if it really made a difference but I have never been zapped when using my thickness sander (I occasionally did when using the shop vac) with the dust collector. My flex hoses are not metalic and therefor not grounded. They are always covered with a film of dist that has been drawn to them. The PVC pipes are mostly in the walls and ceiling so I don't know if they are attracting dust to them or not. It is possible the aluminum tape is having zero effect but it was cheap and easy at the time.
PMoMC

Take care of your feet and your feet will take care of you.
User avatar
Bryan Bear
 
Posts: 1131
Joined: Fri Jan 06, 2012 1:05 pm
Location: St. Louis, MO

Re: Dust Collectors

Postby Eric Baack » Fri Mar 15, 2019 2:19 pm

I use a thein separator on a 55 gallon drum and it does a great job of keeping my shop vac clean.
Eric Baack
 
Posts: 629
Joined: Thu Dec 27, 2012 4:28 pm

Re: Dust Collectors

Postby Barry Daniels » Fri Mar 15, 2019 4:47 pm

I added a diy thein to my traditional dust collector and I think it helped keep more fines out of the filter.
MIMF Staff
Barry Daniels
 
Posts: 2208
Joined: Thu Jan 05, 2012 10:58 am
Location: The Woodlands, Texas

Re: Dust Collectors

Postby Christ Kacoyannakis » Fri Mar 15, 2019 7:17 pm

The main grounding wire from the water main to the ground rod in my yard runs right by my Oneida cyclone dust collector. When I was putting it in, I just screwed a ground wire to the aluminum tubing and attached it to the ground wire. I have not had any sparking issues.
Christ Kacoyannakis
 
Posts: 192
Joined: Sat Jan 07, 2012 8:58 pm

Re: Dust Collectors

Postby Steve Sawyer » Fri Mar 15, 2019 9:29 pm

The static isn't hazardous, but it will give you an uncomfortable poke. My system is ducted with 6" SD PVC, and I know from my prior systems that eventually (within a few months) a film of dust coats the inside of the pipes and the problem disappears. With the new Oneida system I installed a couple of years ago, the shock was strong enough to almost knock me on my butt. I ran some cheap tie-wire in a spiral (about 18 linear inches for every loop) from one end of the main run to the cyclone and grounded it, affixing the spiral wire every couple of feet with a short self-tapping sheet-metal screw that just barely penetrated to the inside. Problem solved.
==Steve==
User avatar
Steve Sawyer
 
Posts: 756
Joined: Wed Jan 02, 2013 2:20 pm
Location: Detroit, Michigan


Return to Tools and Jigs

Who is online

Users browsing this forum: No registered users and 0 guests

Your purchase from these sites helps support the MIMForum, but only if you start at the links below!!!
Amazon music     Amazon books     Amazon tools     Rockler tools     Office Depot    

The MIMF is a member-supported forum, please consider supporting us with a donation, thanks!
 • Book store • Tool store • Links •